PITCHED ROOF WITH SARKING


PITCHED ROOF WITH SARKING

Structure characteristicts:

  • PITCHED ROOF WITH SARKING
  • BREATHER MEMBRANE
  • INSULATION BETWEEN AND UNDER RAFTERS
  • INTERNAL FINISH PLASTERBOARD

Structure advantages:

  • VAPOUR OPEN
  • AIRTIGHT
  • SOUND RESISTANCE
  • SPEED OF INSTALLATION
  • USUALLY TIMBER PARTS INVISIBLE FROM INTERIOR
  • REPLACEMENT OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO B.S.EN.
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.18
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]
ICYNENE H2FOAM LITE (LDC-50)0.19
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.18
ICYNENE H2FOAM FORTE (MDR-210) 0.16
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1SLATES/TILESROOF COVERING
2BATTENSUPPORT STRUCTURE BASED ON ROOF COVERING
3COUNTER BATTENmin.40VENTED AIRSPACE
4BREATHER MEMBRANE0.2WEATHER RESISTANT BARRIER / VAPOUR OPEN MEMBRANE
5SARKINGING BOARDS24 - 30ROOF CEILING
6RAFTER - ICYNENE140RAFTER 120/140, 400-600MM CENTRES / THERMAL INSULATION LAYER
7FURRING CHANNELS -ICYNENE60SUPPORTING STRUCTURE / THERMAL INSULATION LAYER
8PLASTER BOARD12.5INTERNAL FINISH




PITCHED ROOF WITH INSULATION OVER RAFTERS


PITCHED ROOF WITH INSULATION OVER RAFTERS

Structure characteristicts:

  • PITCHED ROF WITH BREATHER MEMBRANE
  • RIGID BOARD INSULATION ABOVE RAFTERS
  • FOAM INSULATION BETWEEN RAFTERS
  • PLASTERBOARD INTERNAL FINISH

Structure advantages:

  • DIFUSION OPEN (DEPENDS ON INSULATION)
  • AIRTIGHT
  • SOUND RESISTANCE
  • SPEED OF INSTALLATION
  • USUALLY TIMBER PARTS INVISIBLE FROM INTERIOR
  • REPLACEMENT OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO B.S.EN.
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.18
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]
ICYNENE H2FOAM LITE (LDC-50)0.24
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.22
ICYNENE H2FOAM FORTE (MDR-210) 0.20
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1SLATES/TILESROOF COVERING
2BATTENSUPPORT STRUCTURE BASED ON ROOF COVERING
3COUNTER BATTENmin. 40VENTED AIRSPACE
4BREATHER MEMBRANE0.2WEATHER RESISTANT BARRIER / VAPOUR OPEN MEMBRANE
5PIR160THERMAL INSULATION LAYER
6RAFTER/ ICYNENE160RAFTER 120/160, 400-600MM CENTRES




PITCHED ROOF WITH BREATHABLE UNDERLAY


PITCHED ROOF WITH BREATHABLE UNDERLAY

Structure characteristicts:

  • PITCHED ROOF WITH BREATHABLE UNDERLAY.

  • THERMAL INSULATION BETWEEN AND OWER TIMBER RAFTERS.

  • WITH PLASTERBOARDS.

  • INTERNAL FINISH

Structure advantages:

  • VAPOUR OPEN

  • AIRTIGHT

  • SOUND RESISTANCE

  • SPEED OF INSTALLATION

  • TIMBER PARTS INVISIBLE FROM INSIDE

  • REPLACEMENT OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO B.S.EN.
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.18
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]
ICYNENE H2FOAM LITE (LDC-50)0.19
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.18
ICYNENE H2FOAM FORTE (MDR-210) 0.16
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1SLATERS/TILESROOF COVERING
2BATTENSUPPORT STRUCTURE BASED ON ROOF COVERING
3BREATHER MEMBRANE0.2WEATHER RESISTANT BARRIER / VAPOUR OPEN MEMBRANE
4RAFTER - ICYNENE140RAFTER 120/140, 400-600MM CENTRES / THERMAL INSULATION LAYER
5FURRING CHANNELS - ICYNENE60SUPPORTING STRUCTURE / THERMAL INSULATION LAYER
6PLASTER BOARD12.5 INTERNAL FINISH




PLASTIC WINDOW HEAD INSULATION


PLASTIC WINDOW HEAD INSULATION

Structure characteristicts:

EXISTING WALL DONE FROM BRICKS, INSULATED WITH THERMAL INSULATION ICYNENE TO BEARING STRUCTURE OF EXTERNAL FINISHING. VENTED AIRSPACE IS CREATED BY SUPPORTING STRUCTURES AND EXTERNAL FINISHING LAYER IS FIXED / GLUED TO THEM.

Structure advantages:

  • DIFUSION OPEN
  • AIRTIGHTEN
  • ACOUSTIC RESISTANCE
  • SPEED OF ERECTION
  • TIMBER PARTS INVISIBLE FROM INTERIOR
  • RENEWABILITY OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.3
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.29
ICYNENE H2FOAM LITE (LDC-50)0.38
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.36
ICYNENE H2FOAM FORTE (MDR-210) 0.32
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1BRICKS / POROTHERM / HELUZ / YTONG450EXISTING BEARING STRUCTURE
2TI ICYNENE - SUPPORTING PROFILES FROM AL, ZINC STEEL, WOOD100THERMAL INSULATION LAYER - BEARING STRUCTURE OF EXTERNAL FINISHING
3AIRSPACE WITH ALLUMINIUM - ZINC Z PROFILE40VENTED AIRSPACE - SUPPORTING STRUCTURE OF EXTERNAL FINISHING
4METAL SHEET / FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN8-35EXTERNAL FINISHING




PLASTIC WINDOW SILL INSULATION


PLASTIC WINDOW SILL INSULATION

Structure characteristicts:

EXISTING WALL DONE FROM BRICKS, INSULATED WITH THERMAL INSULATION ICYNENE TO BEARING STRUCTURE OF EXTERNAL FINISHING. VENTED AIRSPACE IS CREATED BY SUPPORTING STRUCTURES AND EXTERNAL FINISHING LAYER IS FIXED / GLUED TO THEM.

Structure advantages:

  • DIFUSION OPEN
  • AIRTIGHTEN
  • ACOUSTIC RESISTANCE
  • SPEED OF ERECTION
  • TIMBER PARTS INVISIBLE FROM INTERIOR
  • RENEWABILITY OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.3
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.29
ICYNENE H2FOAM LITE (LDC-50)0.38
ICYNENE H2FOAM LITE PLUS (LDC-70)0.36
ICYNENE H2FOAM FORTE (MDR-210) 0.32
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1BRICKS / POROTHERM / HELUZ / YTONG450EXISTING BEARING STRUCTURE
2TI ICYNENE - SUPPORTING PROFILES FROM AL, ZINC STEEL, WOOD100THERMAL INSULATION LAYER - BEARING STRUCTURE OF EXTERNAL FINISHING
3AIRSPACE WITH ALLUMINIUM - ZINC Z PROFILE40VENTED AIRSPACE - SUPPORTING STRUCTURE OF EXTERNAL FINISHING
4METAL SHEET / FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN8-35EXTERNAL FINISHING




PARAPET INSULATION


Structure characteristicts:

EXISTING WALL DONE FROM BRICKS, INSULATED WITH THERMAL INSULATION ICYNENE TO BEARING STRUCTURE OF EXTERNAL FINISHING. VENTED AIRSPACE IS CREATED BY SUPPORTING STRUCTURES AND EXTERNAL FINISHING LAYER IS FIXED / GLUED TO THEM. PERFORATED SHEET METAL ENSURES VENTED AIRSPACE.

Structure advantages:

  • DIFUSION OPEN
  • AIRTIGHTEN
  • ACOUSTIC RESISTANCE
  • SPEED OF ERECTION
  • TIMBER PARTS INVISIBLE FROM INTERIOR
  • RENEWABILITY OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.3
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.29
ICYNENE H2FOAM LITE (LDC-50)0.38
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.36
ICYNENE H2FOAM FORTE (MDR-210)0.32
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1BRICKS / POROTHERM / HELUZ / YTONG450EXISTING BEARING STRUCTURE
2TI ICYNENE - SUPPORTING PROFILES FROM AL, ZINC STEEL, WOOD100THERMAL INSULATION LAYER - BEARING STRUCTURE OF EXTERNAL FINISHING
3AIRSPACE WITH ALLUMINIUM - ZINC Z PROFILE40VENTED AIRSPACE - SUPPORTING STRUCTURE OF EXTERNAL FINISHING
4METAL SHEET / FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN8-35EXTERNAL FINISHING




SOCKLE INSULATION


Structure characteristicts:

EXISTING WALL DONE FROM BRICKS, INSULATED WITH THERMAL INSULATION ICYNENE TO BEARING STRUCTURE OF EXTERNAL FINISHING. VENTED AIRSPACE IS CREATED BY SUPPORTING STRUCTURES AND EXTERNAL FINISHING LAYER IS FIXED / GLUED TO THEM. SOCKLE INSULATION IS DONE BY XPS BOARDS / SMARTISOL 200.

Structure advantages:

  • DIFUSION OPEN
  • AIRTIGHTEN
  • ACOUSTIC RESISTANCE
  • SPEED OF ERECTION
  • TIMBER PARTS INVISIBLE FROM INTERIOR
  • RENEWABILITY OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.3
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.29
ICYNENE H2FOAM LITE (LDC-50)0.38
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.36
ICYNENE H2FOAM FORTE (MDR-210) 0.32
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1BRICKS / POROTHERM / HELUZ / YTONG450EXISTING BEARING STRUCTURE
2TI ICYNENE - SUPPORTING PROFILES FROM AL, ZINC STEEL, WOOD100THERMAL INSULATION LAYER - BEARING STRUCTURE OF EXTERNAL FINISHING
3AIRSPACE WITH ALLUMINIUM - ZINC Z PROFILE40VENTED AIRSPACE - SUPPORTING STRUCTURE OF EXTERNAL FINISHING
4METAL SHEET / FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN8-35EXTERNAL FINISHING




EXISTING MASONRY INSULATION


EXISTING MASONRY INSULATION

Structure characteristicts:

EXISTING WALL DONE FROM BRICKS, INSULATED WITH THERMAL INSULATION ICYNENE TO BEARING STRUCTURE OF EXTERNAL FINISHING. VENTED AIRSPACE IS CREATED BY SUPPORTING STRUCTURES AND EXTERNAL FINISHING LAYER IS FIXED / GLUED TO THEM.

Structure advantages:

  • DIFUSION OPEN
  • AIRTIGHTEN
  • ACOUSTIC RESISTANCE
  • SPEED OF ERECTION
  • TIMBER PARTS INVISIBLE FROM INTERIOR
  • RENEWABILITY OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.3
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.29
ICYNENE H2FOAM LITE (LDC-50)0.38
ICYNENE H2FOAM LITE PLUS (LDC-70)0.36
ICYNENE H2FOAM FORTE (MDR-210) 0.32
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1BRICKS / POROTHERM / HELUZ / YTONG450EXISTING BEARING STRUCTURE
2TI ICYNENE - SUPPORTING PROFILES FROM AL, ZINC STEEL, WOOD100THERMAL INSULATION LAYER - BEARING STRUCTURE OF EXTERNAL FINISHING
3AIRSPACE WITH ALLUMINIUM - ZINC Z PROFILE40VENTED AIRSPACE - SUPPORTING STRUCTURE OF EXTERNAL FINISHING
4METAL SHEET / FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN8-35EXTERNAL FINISHING




PLASTIC WINDOW HEAD INSULATION


PLASTIC WINDOW HEAD INSULATION

Structure characteristicts:

BEARING STEEL STRUCTURE WITH METAL SHEET CLADDING WITH THERMAL INSULATION ICYNENE SPRAYED ON CONTACT DIFUSION FOIL. FOIL IS FIXED TO THE FURRING CHANNELS AND INTERNAL FINISHING IS DONE FROM GYPSUM BOARD.

Structure advantages:

  • DIFUSION OPEN
  • AIRTIGHTEN
  • ACOUSTIC RESISTANCE
  • SPEED OF ERECTION
  • TIMBER PARTS INVISIBLE FROM INTERIOR
  • RENEWABILITY OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.3
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.22
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.20
ICYNENE H2FOAM FORTE (MDR-210) 0.18
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1GYPSUM BOARD15INTERNAL FINISHING
2FURRING CHANNELS60SUPPORTING STRUCTURE
3IPE STEEL PROFIL170STEEL BEARING STRUCTURE
4WÜRTH THERMO ND / STAMISOL0.2DIFFUSION OPEN MEMBRANE
5TI ICYNENE - METSEC PROFILE180THERMAL INSULATION LAYER
6AIRSPACEmin 40VENTED AIRSPACE
7METAL SHEET / FUNDERMAX / CEBRIT / CEMBONIT8-35EXTERNAL FINISHING




PLASTIC WINDOW SILL INSULATION


PLASTIC WINDOW SILL INSULATION

Structure characteristicts:

BEARING STEEL STRUCTURE WITH METAL SHEET CLADDING WITH THERMAL INSULATION ICYNENE SPRAYED ON CONTACT DIFUSION FOIL. FOIL IS FIXED TO THE FURRING CHANNELS AND INTERNAL FINISHING IS DONE FROM GYPSUM BOARD.

Structure advantages:

  • DIFUSION OPEN
  • AIRTIGHTEN
  • ACOUSTIC RESISTANCE
  • SPEED OF ERECTION
  • TIMBER PARTS INVISIBLE FROM INTERIOR
  • RENEWABILITY OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.3
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.22
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70)0.20
ICYNENE H2FOAM FORTE (MDR-210)0.18
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1GYPSUM BOARD15INTERNAL FINISHING
2FURRING CHANNELS60SUPPORTING STRUCTURE
3IPE STEEL PROFIL170STEEL BEARING STRUCTURE
4WÜRTH THERMO ND / STAMISOL0.2DIFFUSION OPEN MEMBRANE
5TI ICYNENE - METSEC PROFILE180THERMAL INSULATION LAYER
6AIRSPACEmin 40VENTED AIRSPACE
7METAL SHEET / FUNDERMAX / CEBRIT / CEMBONIT8-35EXTERNAL FINISHING