BUILD UP WALL CLADDING
Structure characteristicts:
BEARING STEEL STRUCTURE WITH METAL SHEET CLADDING WITH THERMAL INSULATION ICYNENE SPRAYED ON CONTACT DIFUSION FOIL. FOIL IS FIXED TO THE FURRING CHANNELS AND INTERNAL FINISHING IS DONE FROM GYPSUM BOARD.
Structure advantages:
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540 | |||
---|---|---|---|
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K] | 0.3 | ||
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K] | 0.22 | ||
ICYNENE H2FOAM LITE (LDC-50) | 0.21 | ||
ICYNENE H2FOAM LITE PLUS (LDC-70) | 0.20 | ||
ICYNENE H2FOAM FORTE (MDR-210) | 0.18 | ||
TECHNICAL PARAMETERS OF STRUCTURE | |||
LABEL | LAYER | THK. [mm] | DESCRIPTION |
1 | GYPSUM BOARD | 15 | INTERNAL FINISHING |
2 | FURRING CHANNELS | 60 | SUPPORTING STRUCTURE |
3 | IPE STEEL PROFIL | 170 | STEEL BEARING STRUCTURE |
4 | WÜRTH THERMO ND / STAMISOL | 0.2 | DIFFUSION OPEN MEMBRANE |
5 | TI ICYNENE - METSEC PROFILE | 180 | THERMAL INSULATION LAYER |
6 | AIRSPACE | min 40 | VENTED AIRSPACE |
7 | METAL SHEET / FUNDERMAX / CEBRIT / CEMBONIT | 8-35 | EXTERNAL FINISHING |