ZATEPLENÍ STŘEŠNÍ ATIKY


ZATEPLENÍ STŘEŠNÍ ATIKY

Charakteristika skladby:

OBVODOVÁ NOSNÁ OCELOVÁ KONSTRUKCE OPLÁŠTĚNÁ Z VNĚJŠÍ STRANY TRAPÉZOVÝM PLECHEM, KTERÁ JE ZAIZOLOVÁNA IZOLACÍ ICYNENE NA KONTAKTNÍ DIFÚZNÍ FÓLIÍ, KTERÁ JE KOTVENA NA CD PROFILY SÁDROKARTÓNOVÉ PŘEDSTĚNY A VNITŘNÍ POVRCHOVÁ ÚPRAVA JE TVOŘENA SDK DESKOU. STŘEŠNÍ NOSNÁ KONSTRUKCE JE NAVRŽENA Z TREPÉZOVÝCH PLECHŮ, KTERÉ JSOU ZATEPLENY SKLÁDANÝM SYSTÉMEM Z EPS NEBO MINERÁLNÍ VATOU A HYDROIZOOLAČNÍ VRSTVOU Z PVC FÓLIE.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • RYCHLOST VÝSTAVBY
  • PESTROST POUŽITÍ VNĚJŠÍCH OBKLADOVÝCH MATERIÁLŮ
  • OBNOVITELNOST STÁVAJÍCÍ IZOLACE BEZ ZÁSAHU DO INTERIÉRU
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.3
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.22
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70)0.20
ICYNENE H2FOAM FORTE (MDR-210)0.18
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1SADROKARTÓNOVÁ DESKA15VNITŘNÍ POVRCHOVÁ ÚPRAVA
2SDK ROŠT Z CD PROFILŮ60SADROKARTÓNOVÁ KONSTRUKCE
3OCELOVÝ IPE PROFIL170OCELOVÁ NOSNÁ KONSTRUKCE
4WÜRTH THERMO ND / STAMISOL0.2KONTAKTNÍ - DIFUZNĚ OTEVŘENÁ FOLIE
5TI ICYNENE180TEPELNĚ IZOLAČNÍ VRSTVA
6VZDUCHOVÁ MEZERA40VĚTRANÁ VZDUCHOVÁ MEZERA
7TRAPÉZOVÝ PLECH35VNĚJŠÍ POVRCHOVÁ ÚPRAVA (NAPŘ. TRAPÉZOVÝ PLECH, FUNDERMAX, CEBRIT, CEMBONIT)




UKONČENÍ ZATEPLENÍ U OKAPU


UKONČENÍ ZATEPLENÍ U OKAPU

Charakteristika skladby:

OBVODOVÁ NOSNÁ OCELOVÁ KONSTRUKCE OPLÁŠTĚNÁ Z VNĚJŠÍ STRANY TRAPÉZOVÝM PLECHEM, KTERÁ JE ZAIZOLOVÁNA IZOLACÍ ICYNENE NA KONTAKTNÍ DIFÚZNÍ FÓLIÍ, KTERÁ JE KOTVENA NA CD PROFILY SÁDROKARTÓNOVÉ PŘEDSTĚNY A VNITŘNÍ POVRCHOVÁ ÚPRAVA JE TVOŘENA SDK DESKOU. ZASTŘEŠENÍ JE PROVEDENO PUR PANELEM A PROVĚTRÁVANÁ MEZERA UKONČENA PERFOROVANÝM PLECHEM.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • RYCHLOST VÝSTAVBY
  • PESTROST POUŽITÍ VNĚJŠÍCH OBKLADOVÝCH MATERIÁLŮ
  • OBNOVITELNOST STÁVAJÍCÍ IZOLACE BEZ ZÁSAHU DO INTERIÉRU
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.3
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.22
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70)0.20
ICYNENE H2FOAM FORTE (MDR-210) 0.18
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1SADROKARTÓNOVÁ DESKA15VNITŘNÍ POVRCHOVÁ ÚPRAVA
2SDK ROŠT Z CD PROFILŮ60SADROKARTÓNOVÁ KONSTRUKCE
3OCELOVÝ IPE PROFIL170OCELOVÁ NOSNÁ KONSTRUKCE
4WÜRTH THERMO ND / STAMISOL0.2KONTAKTNÍ - DIFUZNĚ OTEVŘENÁ FOLIE
5TI ICYNENE180TEPELNĚ IZOLAČNÍ VRSTVA
6VZDUCHOVÁ MEZERA40VĚTRANÁ VZDUCHOVÁ MEZERA
7TRAPÉZOVÝ PLECH35VNĚJŠÍ POVRCHOVÁ ÚPRAVA (NAPŘ. TRAPÉZOVÝ PLECH, FUNDERMAX, CEBRIT, CEMBONIT)




NAPOJENÍ SOKLOVÉHO ZDIVA


NAPOJENÍ SOKLOVÉHO ZDIVA

Charakteristika skladby:

OBVODOVÁ NOSNÁ OCELOVÁ KONSTRUKCE OPLÁŠTĚNÁ Z VNĚJŠÍ STRANY TRAPÉZOVÝM PLECHEM, KTERÁ JE ZAIZOLOVÁNA IZOLACÍ ICYNENE NA KONTAKTNÍ DIFÚZNÍ FÓLIÍ, KTERÁ JE KOTVENA NA CD PROFILY SÁDROKARTÓNOVÉ PŘEDSTĚNY A VNITŘNÍ POVRCHOVÁ ÚPRAVA JE TVOŘENA SDK DESKOU. ZATEPLENÍ SOKLOVÉHO ZDIVA PROVEDENO IZOLACÍ XPS.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • RYCHLOST VÝSTAVBY
  • PESTROST POUŽITÍ VNĚJŠÍCH OBKLADOVÝCH MATERIÁLŮ
  • OBNOVITELNOST STÁVAJÍCÍ IZOLACE BEZ ZÁSAHU DO INTERIÉRU
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.3
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.22
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70)0.20
ICYNENE H2FOAM FORTE (MDR-210)0.18
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1SADROKARTÓNOVÁ DESKA15VNITŘNÍ POVRCHOVÁ ÚPRAVA
2SDK ROŠT Z CD PROFILŮ60SADROKARTÓNOVÁ KONSTRUKCE
3OCELOVÝ IPE PROFIL170OCELOVÁ NOSNÁ KONSTRUKCE
4WÜRTH THERMO ND / STAMISOL0.2KONTAKTNÍ - DIFUZNĚ OTEVŘENÁ FOLIE
5TI ICYNENE180TEPELNĚ IZOLAČNÍ VRSTVA
6VZDUCHOVÁ MEZERA40VĚTRANÁ VZDUCHOVÁ MEZERA
7TRAPÉZOVÝ PLECH35VNĚJŠÍ POVRCHOVÁ ÚPRAVA (NAPŘ. TRAPÉZOVÝ PLECH, FUNDERMAX, CEBRIT, CEMBONIT)




SKLÁDANÝ OBVODOVÝ PLÁŠŤ


SKLÁDANÝ OBVODOVÝ PLÁŠŤ

Charakteristika skladby:

OBVODOVÁ NOSNÁ OCELOVÁ KONSTRUKCE OPLÁŠTĚNÁ Z VNĚJŠÍ STRANY TRAPÉZOVÝM PLECHEM, KTERÁ JE ZAIZOLOVÁNA IZOLACÍ ICYNENE NA KONTAKTNÍ DIFÚZNÍ FÓLIÍ, KTERÁ JE KOTVENA NA CD PROFILY SÁDROKARTÓNOVÉ PŘEDSTĚNY A VNITŘNÍ POVRCHOVÁ ÚPRAVA JE TVOŘENA SDK DESKOU.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • RYCHLOST VÝSTAVBY
  • PESTROST POUŽITÍ VNĚJŠÍCH OBKLADOVÝCH MATERIÁLŮ
  • OBNOVITELNOST STÁVAJÍCÍ IZOLACE BEZ ZÁSAHU DO INTERIÉRU
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.3
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.22
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.20
ICYNENE H2FOAM FORTE (MDR-210)0.18
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1SADROKARTÓNOVÁ DESKA15VNITŘNÍ POVRCHOVÁ ÚPRAVA
2SDK ROŠT Z CD PROFILŮ60SADROKARTÓNOVÁ KONSTRUKCE
3OCELOVÝ IPE PROFIL170OCELOVÁ NOSNÁ KONSTRUKCE
4WÜRTH THERMO ND / STAMISOL0.2KONTAKTNÍ - DIFUZNĚ OTEVŘENÁ FOLIE
5TI ICYNENE180TEPELNĚ IZOLAČNÍ VRSTVA
6VZDUCHOVÁ MEZERA40VĚTRANÁ VZDUCHOVÁ MEZERA
7TRAPÉZOVÝ PLECH35VNĚJŠÍ POVRCHOVÁ ÚPRAVA (NAPŘ. TRAPÉZOVÝ PLECH, FUNDERMAX, CEBRIT, CEMBONIT)




ZATEPLENÍ OBVODOVÉHO ZDIVA


ZATEPLENÍ OBVODOVÉHO ZDIVA

Charakteristika skladby:

DIFÚZNĚ OTEVŘENÁ KONSTRUKCE S PROVĚTRÁVANOU MEZEROU, KTERÉ JE TVOŘENA HLINÍKOVÝM ROŠTĚM S TEPELNOU IZOLACÍ ICYNENE.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • ČLENITOST – RŮZNÉ MOŽNOSTI POVRCHŮ
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.30
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.18
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70)0.20
ICYNENE H2FOAM FORTE (MDR-210)0.18
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1DESKA FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN8VNĚJŠÍ POVRCHOVÁ ÚPRAVA 1)
2LEPIDLO SIKA3SPOJOVACÍ VRSTVA
3HLINÍKOVÝ L PROFIL80NOSNÁ KONSTRUKCE
4PROVĚTRÁVANÁ MEZERA40VZDUCHOVÁ MEZERA
5VYNÁŠECÍ ROŠT VYNÁŠECÍ ROŠT HAFIX / ILTEGRO - TI ICYNENE100NOSNÝ ROŠT / TEPELNĚ IZOLAČNÍ VRSTVA
6POROTHERM / HELUZ / YTONG440OBVODOVÉ ZDIVO POROTHERM P+D
Poznámka:1) POKUD BUDOU MEZERY MEZI FINÁLNÍM POHLEDOVÝM MATERIÁLEM JE POTŘEBA OCHRÁNIT TEPELNOU IZOLACÍ POMOCÍ DIFÚZNÍ FÓLIE NEBO UV NÁTĚREM




ZATEPLENÍ OBVODOVÉHO ZDIVA - PARAPET


ZATEPLENÍ OBVODOVÉHO ZDIVA – NADPRAŽÍ

Charakteristika skladby:

DIFÚZNĚ OTEVŘENÁ KONSTRUKCE S PROVĚTRÁVANOU MEZEROU, KTERÉ JE TVOŘENA HLINÍKOVÝM ROŠTĚM S TEPELNOU IZOLACÍ ICYNENE.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • ČLENITOST – RŮZNÉ MOŽNOSTI POVRCHŮ
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.30
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.18
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70)0.20
ICYNENE H2FOAM FORTE (MDR-210)0.18
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1DESKA FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN8VNĚJŠÍ POVRCHOVÁ ÚPRAVA 1)
2LEPIDLO SIKA3SPOJOVACÍ VRSTVA
3HLINÍKOVÝ L PROFIL80NOSNÁ KONSTRUKCE
4PROVĚTRÁVANÁ MEZERA40VZDUCHOVÁ MEZERA
5VYNÁŠECÍ ROŠT VYNÁŠECÍ ROŠT HAFIX / ILTEGRO - TI ICYNENE100NOSNÝ ROŠT / TEPELNĚ IZOLAČNÍ VRSTVA
6POROTHERM / HELUZ / YTONG440OBVODOVÉ ZDIVO POROTHERM P+D
Poznámka:1) POKUD BUDOU MEZERY MEZI FINÁLNÍM POHLEDOVÝM MATERIÁLEM JE POTŘEBA OCHRÁNIT TEPELNOU IZOLACÍ POMOCÍ DIFÚZNÍ FÓLIE NEBO UV NÁTĚREM




ZATEPLENÍ OBVODOVÉHO ZDIVA - NADPRAŽÍ


ZATEPLENÍ OBVODOVÉHO ZDIVA – NADPRAŽÍ

Charakteristika skladby:

DIFÚZNĚ OTEVŘENÁ KONSTRUKCE S PROVĚTRÁVANOU MEZEROU, KTERÉ JE TVOŘENA HLINÍKOVÝM ROŠTĚM S TEPELNOU IZOLACÍ ICYNENE.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • ČLENITOST – RŮZNÉ MOŽNOSTI POVRCHŮ
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.30
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.18
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70)0.20
ICYNENE H2FOAM FORTE (MDR-210)0.18
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1DESKA FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN8VNĚJŠÍ POVRCHOVÁ ÚPRAVA 1)
2LEPIDLO SIKA3SPOJOVACÍ VRSTVA
3HLINÍKOVÝ L PROFIL80NOSNÁ KONSTRUKCE
4PROVĚTRÁVANÁ MEZERA40VZDUCHOVÁ MEZERA
5VYNÁŠECÍ ROŠT VYNÁŠECÍ ROŠT HAFIX / ILTEGRO - TI ICYNENE100NOSNÝ ROŠT / TEPELNĚ IZOLAČNÍ VRSTVA
6POROTHERM / HELUZ / YTONG440OBVODOVÉ ZDIVO POROTHERM P+D
Poznámka:1) POKUD BUDOU MEZERY MEZI FINÁLNÍM POHLEDOVÝM MATERIÁLEM JE POTŘEBA OCHRÁNIT TEPELNOU IZOLACÍ POMOCÍ DIFÚZNÍ FÓLIE NEBO UV NÁTĚREM




ZATEPLENÍ STŘEŠNÍHO OKNA - HORNÍ ČÁST


ZATEPLENÍ STŘEŠNÍHO OKNA – HORNÍ ČÁST

Charakteristika skladby:

ŠIKMÁ STŘECHA BEZ STŘEŠNÍHO ZÁKLOPU S DŘEVĚNOU NOSNOU KONSTRUKCÍ (KROV), S TEPELNOU IZOLACÍ MEZI KROKVEMI A POD NIMI. DOPLŇKOVÁ HYDROIZOLAČNÍ VRSTVA JE TVOŘENA KONTAKTNÍ DIFÚZNÍ FÓLIÍ. POHLEDOVÁ VRSTVA ZE STRANY INTERIÉRU JE TVOŘENA SÁDROKARTÓNOVÝMI DESEKAMI. ZATEPLENÍ OSTĚNÍ STŘEŠNÍHO OKNA V MINIMÁLNÍ TLOUŠŤCE 80 MM Z DŮVODU MOŽNÉ KONDENZACE.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • NEVIDITELNOST DŘEVĚNÝCH PRVKŮ KROVU ZE STRANY INTERIÉRU
  • OBNOVITELNOST STÁVAJÍCÍ IZOLACE BEZ ZÁSAHU DO INTERIÉRU
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.24
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.23
ICYNENE H2FOAM LITE (LDC-50)0.19
ICYNENE H2FOAM LITE PLUS (LDC-70)0.18
ICYNENE H2FOAM FORTE (MDR-210)0.16
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1BRAMAC / TONDACH / PLECHOVÁ KRYTINA APOD. STŘEŠNÍ KRYTINA
2ROZNÁŠECí LAŤOVÁNíPODKLADNí KCE DLE TYPU KRYTINY
3KONTRALATĚmin. 40VĚTRANÁ VZDUCHOVÁ MEZERA
4WURTH THERMO ND / DORKEN DELTA-MAXX / TYVEK SUPRO0.2DOPLŇKOVÁ HYDROIZOLAČNI VRSTVA, KONTAKTNÍ-DIFÚZNĚ OTEVŘENÁ
5KROKEV / TI ICYNENE140KROKEV 120/140 OSOVÁ VZDÁLENOST 0,9 m / TEPELNĚ IZOLAČNÍ VRSTVA
6SÁDROKARTÓNOVÝ ROŠT / TI ICYNENE60POMOCNÁ VYNÁŠECí KCE / TEPELNĚ IZOLAČNÍ VRSTVA
7SÁDROKARTÓNOVÁ DESKA12.5POVRCHOVÁ ÚPRAVA




ZATEPLENÍ STŘEŠNÍHO OKNA - DOLNÍ ČÁST


ZATEPLENÍ STŘEŠNÍHO OKNA – DOLNÍ ČÁST

Charakteristika skladby:

ŠIKMÁ STŘECHA BEZ STŘEŠNÍHO ZÁKLOPU S DŘEVĚNOU NOSNOU KONSTRUKCÍ (KROV), S TEPELNOU IZOLACÍ MEZI KROKVEMI A POD NIMI. DOPLŇKOVÁ HYDROIZOLAČNÍ VRSTVA JE TVOŘENA KONTAKTNÍ DIFÚZNÍ FÓLIÍ. POHLEDOVÁ VRSTVA ZE STRANY INTERIÉRU JE TVOŘENA SÁDROKARTÓNOVÝMI DESEKAMI. ZATEPLENÍ OSTĚNÍ STŘEŠNÍHO OKNA V MINIMÁLNÍ TLOUŠŤCE 80 MM Z DŮVODU MOŽNÉ KONDENZACE.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • NEVIDITELNOST DŘEVĚNÝCH PRVKŮ KROVU ZE STRANY INTERIÉRU
  • OBNOVITELNOST STÁVAJÍCÍ IZOLACE BEZ ZÁSAHU DO INTERIÉRU
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.24
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.23
ICYNENE H2FOAM LITE (LDC-50)0.19
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.18
ICYNENE H2FOAM FORTE (MDR-210)0.16
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1BRAMAC / TONDACH / PLECHOVÁ KRYTINA APOD. STŘEŠNÍ KRYTINA
2ROZNÁŠECí LAŤOVÁNíPODKLADNí KCE DLE TYPU KRYTINY
3KONTRALATĚmin. 40VĚTRANÁ VZDUCHOVÁ MEZERA
4WURTH THERMO ND / DORKEN DELTA-MAXX / TYVEK SUPRO0.2DOPLŇKOVÁ HYDROIZOLAČNI VRSTVA, KONTAKTNÍ-DIFÚZNĚ OTEVŘENÁ
5KROKEV / TI ICYNENE140KROKEV 120/140 OSOVÁ VZDÁLENOST 0,9 m / TEPELNĚ IZOLAČNÍ VRSTVA
6SÁDROKARTÓNOVÝ ROŠT / TI ICYNENE60POMOCNÁ VYNÁŠECí KCE / TEPELNĚ IZOLAČNÍ VRSTVA
7SÁDROKARTÓNOVÁ DESKA12.5POVRCHOVÁ ÚPRAVA




ZATEPLENÍ POZEDNICE


Charakteristika skladby:

ŠIKMÁ STŘECHA BEZ STŘEŠNÍHO ZÁKLOPU S DŘEVĚNOU NOSNOU KONSTRUKCÍ (KROV), S TEPELNOU IZOLACÍ MEZI KROKVEMI A POD NIMI. DOPLŇKOVÁ HYDROIZOLAČNÍ VRSTVA JE TVOŘENA KONTAKTNÍ DIFÚZNÍ FÓLIÍ. POHLEDOVÁ VRSTVA ZE STRANY INTERIÉRU JE TVOŘENA ZE SÁDROKARTÓNOVÝCH DESEK.

Přednosti skladby:

  • DIFÚZNÍ OTEVŘENOST
  • VZDUCHOTĚSNOT
  • AKUSTICKÁ ODOLNOST
  • NEVIDITELNOST DŘEVĚNÝCH PRVKŮ KROVU ZE STRANY INTERIÉRU
  • OBNOVITELNOST STÁVAJÍCÍ IZOLACE BEZ ZÁSAHU DO INTERIÉRU
SOUČINITEL PROSTUPU TEPLA DLE ČSN 730540
POŽADOVANÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.24
VYPOČTENÁ HODNOTA SOUČINITELE PROSTUPU TEPLA U [W/m2K]0.23
ICYNENE H2FOAM LITE (LDC-50)0.19
ICYNENE H2FOAM LITE PLUS (LDC-70)0.18
ICYNENE H2FOAM FORTE (MDR-210) 0.16
TECHNICKÉ PARAMETRY SKLADBY
OZNVRSTVATL. [mm]POPIS
1BRAMAC / TONDACH / PLECHOVÁ KRYTINA APOD. STŘEŠNÍ KRYTI NA
2ROZNÁŠECí LAŤOVÁNíPODKLADNí KCE DLE TYPU KRYTINY
3KONTRALATĚmin. 40VĚTRANÁ VZDUCHOVÁ MEZERA
4WURTH THERMO ND / DORKEN DELTA-MAXX / TYVEK SUPRO0.2DOPLŇKOVÁ HYDROIZOLAČNI VRSTVA, KONTAKTNÍ-DIFÚZNĚ OTEVŘENÁ
5KROKEV / TI ICYNENE140KROKEV 120/140 OSOVÁ VZDÁLENOST 0,9 m / TEPELNĚ IZOLAČNÍ VRSTVA
6SÁDROKARTÓNOVÝ ROŠT / TI ICYNENE60POMOCNÁ VYNÁŠECí KCE / TEPELNĚ IZOLAČNÍ VRSTVA
7SÁDROKARTÓNOVÁ DESKA12.5POVRCHOVÁ ÚPRAVA