COMBLE A PENTES AVEC ISOLATION SUR LES CHEVRONS


COMBLE A PENTES AVEC ISOLATION SUR LES CHEVRONS

CARACTÉRISTIQUES DE CONCEPTION:

COMBLE A PENTES AVEC DALLE DE PLANCHER AVEC LA STRUCTURE PORTEUSE EN BOIS, AVEC UNE ISOLATION THERMIQUE SUR LES CHEVRONS. AU DESSUS DE CHEVRONS XPS SONT FIXÉS A L’AIDE DE PANNEAUX EN BOIS. LA COUCHE SUPPLÉMENTAIRE DE L’ISOLATION HYDROFUGE EST FAITE DU FILM SUPER DIFFUS.

AVANTAGES DE LA CONSTRUCTION:

  • PERMÉABILITÉ À LA VAPEUR
  • ÉTANCHÉITÉЬ
  • RÉSISTANCE ACOUSTIQUE
  • PIÈCES DE BOIS NE SONT PAS VISIBLES DE L’INTÉRIEUR
  • REPRISE DE L’ISOLATION EXISTANTE SANS INTERVENTION À L’INTÉRIEUR
CONDUCTIVITÉ THERMIQUE EN FONCTION DE CSN 730540
VALEUR REQUISE DE LA CONDUCTIVITÉ THERMIQUE U [W/m2K] 0.24
VALEUR CALCULÉE DE LA CONDUCTIVITÉ THERMIQUE U [W/m2K]0.23
ICYNENE H2FOAM LITE (LDC-50)0.24
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.22
ICYNENE H2FOAM FORTE (MDR-210) 0.20
PARAMETRES TECHNIQUES DE LA CONSTRUCTION
MARQUECOUCHETL [mm]DÉSCRIPTION
1TUILE / ARDOISE MÉTALLIQUEREVÉTEMENT DE TOITURE
2LATTECHARPENTE DE TOITURE
3CONTRELATTEMIN 40COUCHE D’AIR
4MEMBRANE SUPER DIFFUSE / DORKEN DELTA-MAXX / TYVEK SUPRO0.2COUCHE D’HYDRO-BARRIERE / MEMBRANE ÉTANCHE À LA VAPEUR
5TI ICYNENE / XPS160COUCHE D’ISOLATION THERMIQUE 1)
6AIS / BARRE OSB / FEUILLE DE PLACAGE15 - 30PARÉMENT INTÉRIEUR AVEC LES CARACTÉRISTIQUES D’INHIBITATION DE LA VAPEUR
7CHEVRON160CHEVRON 120/160, DISTANCE 0.9 m
Mention:LE POLYSTYROL EXTRUDÉ EST UTILISÉ AU DESSUS DES CHEVRONS. LA FIXATION EST FAITE A L’AIDE DE PANNEAUX EN BOIS, CE QUI DONNE LA POSSIBILITÉ DE MONTAGE DE LA MEMBRANE ÉTANCHE A LA VAPEUR.




COMBLE A PENTES SANS DALLE DE PLANCHER


COMBLE A PENTES SANS DALLE DE PLANCHER

CARACTÉRISTIQUES DE CONCEPTION:

COMBLE A PENTES SANS DALLE DE PLANCHER AVEC LA STRUCTURE PORTEUSE EN BOIS, AVEC UNE ISOLATION THERMIQUE ENTRE ET SOUS LES CHEVRONS. LA COUCHE SUPPLÉMENTAIRE DE L’ISOLATION HYDROFUGE DU FILM SUPER DIFFUS. LE PARÉMENT INTÉRIEUR EST FAIT DE PLACOPLÂTRE.

AVANTAGES DE LA CONSTRUCTION:

  • PERMÉABILITÉ À LA VAPEUR
  • ÉTANCHÉITÉ
  • RÉSISTANCE ACOUSTIQUE
  • PIÈCES DE BOIS NE SONT PAS VISIBLES DE L’INTÉRIEUR
  • REPRISE DE L’ISOLATION EXISTANTE SANS INTERVENTION À L’INTÉRIEUR
CONDUCTIVITÉ THERMIQUE mmU [W/m2K]
ICYNENE H2FOAM LITE (LDC-50)2500.15
ICYNENE H2FOAM LITE PLUS (LDC-70) -0.14
PARAMETRES TECHNIQUES DE LA CONSTRUCTION
MARQUEELEMENTSTL [mm]DESCRIPTION
1TUILE/ARDOISEPIECES DE COUVERTURE
2,3LATTE, CONTRELATTEPIECES DE BOIS
4MEMBRANE / DORKEN DELTA MAXX / TYVEK SUPRO0.2ECRAN DE SOUS TOITURE H.P.V. (HAUTEMENT PERMEABLE A LA VAPEUR D’EAU)
5CHEVRON ET MOUSSE ISOLANTE ICYNENE250ELEMENTS DE CHARPENTE ET EPAISSEUR DE MOUSSE
6RAIL, FOURRURE, LISSE, SYSTEME DE FIXATION-OSSATURE METALLIQUE
7PLAQUES DE PLATRE12.5PAREMENT INTERIEUR




ISOLATION THERMIQUE DE MUR MACONNE, FINITION ENDUIT


ISOLATION THERMIQUE DE MUR MACONNE, FINITION ENDUIT

DESCRIPTION:

ISOLATION THERMIQUE DE MUR MACONNE, FINITION EXTERIEURE AVEC ENDUIT.
LA FACADE EXTERIEURE DU MUR SERT DE SUPPORT DE PROJECTION.
UNE OSSATURE METALLIQUE OU BOIS FIXEE MECANIQUEMENT SUR LA FACADE PERMET LA FIXATION D’UN ECRAN PARE PLUIE ET DU SYSTEME DE FINITION SOUS ENDUIT.

AVANTAGES DE LA CONSTRUCTION:

  • PERMÉABILITÉ A LA VAPEUR D’EAU
  • ÉTANCHÉITÉ A L’AIR
  • AFFAIBLISSEMENT ACOUSTIQUE
  • DIMINUTION DES PONTS THERMIQUES
  • GRAND CHOIX DE FINITIONS D’ENDUIT
CONDUCTIVITÉ THERMIQUE
ICYNENE H2FOAM LITE (LDC-50)2000.19
ICYNENE H2FOAM LITE PLUS (LDC-70)-0.18
ICYNENE H2FOAM FORTE (MDR-210)1800.17
PARAMETRES TECHNIQUES DE LA CONSTRUCTION
REF.ÉLÉMENTSmmDÉSCRIPTION
1SYSTEME DE FINITION SOUS ENDUIT6/16PAREMENT EXTERIEUR
2MEMBRANE / DORKEN DELTA MAXX / TYVEK SUPRO0.2ECRAN PARE PLUIE H.P.V. (HAUTEMENT PERMEABLE A LA VAPEUR D’EAU)
3RAIL, FOURRURE, LISSE, SYSTEME DE FIXATION-OSSATURE METALLIQUE OU BOIS
4MOUSSE ISOLANTE ICYNENE200/180EPAISSEUR DE MOUSSE
5BLOC BETON, BRIQUE PLEINE OU CREUSEde 6 à 16
200/400
ELEMENT DE MACONNERIE




ISOLATION THERMIQUE DE MUR MACONNE, FINITION BARDAGE


ISOLATION THERMIQUE DE MUR MACONNE, FINITION BARDAGE

DESCRIPTION:

I.T.E. ISOLATION THERMIQUE PAR L’EXTERIEUR
JONCTION AVEC UN APPUI DE FENETRE

ISOLATION THERMIQUE DE MUR MACCONE,
FINITION EXTERIEURE AVEC BARDAGE
LA FACADE EXTERIEURE DU MUR SERT DE SUPPORT DE PROJECTION.
UNE OSSATURE METALLIQUE OU BOIS FIXEE
MECANIQUEMENT SUR LA FACADE PERMET
L’ACCROCHE DE DIFFERENT TYPES DE BARDAGES

AVANTAGES DE LA CONSTRUCTION:

  • PERMEABILITE A LA VAPEUR D’EAU
  • ETANCHEITE A L’AIR
  • AFFAIBLISSEMENT ACOUSTIQUE
  • DIMINUTION DES PONTS THERMIQUES
  • UN GRAND CHOIX DE BARDAGES EXTERIEURS
CONDUCTIVITE THERMIQUEMM U [W/m2K]
ICYNENE H2FOAM LITE (LDC-50)
2000.19
ICYNENE H2FOAM LITE PLUS (LDC-70) -0.18
ICYNENE H2FOAM FORTE (MDR-210) 1800.17
PARAMETRES TECHNIQUES DE LA CONSTRUCTION
MARQUEELEMENTSTL [mm]DESCRIPTION
1BARDAGE-PAREMENT EXTERIEUR
2MEMBRANE / DORKEN DELTA MAXX / TYVEK SUPRO0.2ECRAN PARE PLUIE H.P.V. (HAUTEMENT PERMEABLE A LA VAPEUR D’EAU)
3LAME D'AIR40
4RAIL, FOURRURE, LISSE, SYSTEME DE FIXATION-OSSATURE METALLIQUE
5MOUSSE ISOLANTE ICYNENE200/180ELEMENTS DE CHARPENTE METAL OU BOIS ET EPAISSEUR DE MOUSSE
6BLOC BETON. BRIQUE200/400ELEMENTS DE MACONNERIE




EXTERNAL MASONRY INSULATION - HEAD


EXTERNAL MASONRY INSULATION – HEAD

Structure characteristicts:

DIFUSION OPEN STRUCTURE WITH VENTED AIRSPACE DONE FROM ALLUMINIUM PROFILES AND THERMAL INSULATION ICYNENE

Structure advantages:

  • VAPOUR OPEN

  • AIRTIGHT

  • SOUND RESISTANCE

  • SPEED OF INSTALLATION
  • SEGMENTATION – VARIOUS SURFACES OPTIONS
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.3
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.20
ICYNENE H2FOAM FORTE (MDR-210) 0.18
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN BOARD8EXTERIOR FINISH
2SIKA GLUE3CONNECTING LAYER
3AIRSPACE40VENTED AIRSPACE
4FURRING CHANNELS HAFIX / INTEGRO - TI ICYNENE180SUPPORTING STRUCTURE / THERMAL INSULATION LAYER
5POROTHERM / HELUZ / YTONG440EXTERNAL MASONRY
Remark:1] THERMAL INSULATION HAS TO BE PROTECTED WITH VAPOR BARRIER OR UV PAINT IN CASE OF GAPS BETWEEN EXTERNAL FINISHING BOARDS.

 

 




ISOLATION THERMIQUE DE RAMPANTS DE COMBLES HABITABLES


ISOLATION THERMIQUE DE RAMPANTS DE COMBLES HABITABLES

DESCRIPTION:

I.T.I. ISOLATION THERMIQUE PAR L’INTERIEUR
TRAITEMENT DE POINTS SINGULIERS : JONCTION AVEC FENETRE DE TOIT, PARTIE SUPERIEURE
ISOLATION THERMIQUE DE RAMPANTS DE COMBLES HABITABLES
LE SUPPORT DE PROJECTION EST UN FILM H.P.V.
CONTINUITE DE L’ISOLATION A LA PERIPHERIE DE LA FENETRE DE TOIT
LE PAREMENT INTERIEUR, FIXE MECANIQUEMENT SUR UNE OSSATURE METALLIQUE EST UNE PLAQUE DE PLATRE.

AVANTAGES DE LA CONSTRUCTION:

  • PERMEABILITE A LA VAPEUR D’EAU
  • ETANCHEITE A L’AIR
  • AFFAIBLISSEMENT ACOUSTIQUE
  • ELIMINE LES PONTS THERMIQUES
  • REDUIT LE RISQUE DE CONDENSATION
CONDUCTIVITÉ THERMIQUEmmU [W/m2K]
ICYNENE H2FOAM LITE (LDC-50)2500.15
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.14
PARAMETRES TECHNIQUES DE LA CONSTRUCTION
MARQUEELEMENTSTL [mm]DESCRIPTION
1TUILE / ARDOISEPIECES DE COUVERTURE
2,3LATTE & CONTRELATTEPIECES DE BOIS
4MEMBRANE / DORKEN DELTA MAXX / TYVEK SUPRO0.2ECRAN DE SOUS TOITURE H.P.V. (HAUTEMENT PERMEABLE A LA VAPEUR D’EAU)
5CHEVRON ET MOUSSE ISOLANTE ICYNENE250ELEMENTS DE CHARPENTE ET EPAISSEUR DE MOUSSE
6RAIL, FOURRURE, LISSE, SYSTEME DE FIXATIONOSSATURE METALLIQUE
7PLAQUES DE PLATRE12.5PAREMENT INTERIEUR




ISOLATION THERMIQUE DE RAMPANTS DE COMBLES HABITABLES


ISOLATION THERMIQUE DE RAMPANTS DE COMBLES HABITABLES

DESCRIPTION

I.T.I. : ISOLATION THERMIQUE PAR L’INTERIEUR
TRAITEMENT DE POINTS SINGULIERS : JONCTION AVEC FENETRE DE TOIT, PARTIE INFERIEURE
ISOLATION THERMIQUE DE RAMPANTS DE COMBLES HABITABLES
LE SUPPORT DE PROJECTION EST UN FILM H.P.V.
CONTINUITE DE L’ISOLATION A LA PERIPHERIE DE LA FENETRE DE TOIT
LE PAREMENT INTERIEUR, FIXE MECANIQUEMENT SUR UNE OSSATURE METALLIQUE EST UNE PLAQUE DE PLATRE.

AVANTAGES DE LA CONSTRUCTION:

  • PERMEABILITE A LA VAPEUR D’EAU
  • ETANCHEITE A L’AIR
  • AFFAIBLISSEMENT ACOUSTIQUE
  • ELIMINE LES PONTS THERMIQUES
  • REDUIT LE RISQUE DE CONDENSATION
CONDUCTIVITÉ THERMIQUE mmU [W/m2K]
ICYNENE H2FOAM LITE (LDC-50)2500.15
ICYNENE H2FOAM LITE PLUS (LDC-70) -0.14
PARAMETRES TECHNIQUES DE LA CONSTRUCTION
MARQUEELEMENTSTL [mm]DESCRIPTION
1TUILE / ARDOISE PIECES DE COUVERTURE
2, 3LATTE, CONTRELATTEPIECES DE BOIS
4MEMBRANE / DORKEN DELTA-MAXX / TYVEK SUPRO0.2ECRAN DE SOUS TOITURE H.P.V. (HAUTEMENT PERMEABLE A LA VAPEUR D’EAU)
5CHEVRON ET MOUSSE ISOLANTE ICYNENE250ELEMENTS DE CHARPENTE ET EPAISSEUR DE MOUSSE
6RAIL, FOURRURE, LISSE, SYSTEME DE FIXATION-OSSATURE METALLIQUE
7PLAQUES DE PLATRE12.5PAREMENT INTERIEUR




ISOLATION THERMIQUE DE MUR MACONNE


ISOLATION THERMIQUE DE MUR MACONNE

DESCRIPTION:

I.T.I.: ISOLATION THERMIQUE PAR L’INTERIEUR
TRAITEMENT DE PONTS SINGULIERS: VENTILATION DE LA TOITURE AU DROIT DU FAITAGE.

ISOLATION THERMQUE DE MUR MACONNE
LE SUPPORT DE PROTECTION EST LA FACE INTERIEURE EN BLOCS DE BETON OU BRIQUES.
LE PAREMENT INTERIEUR, FIXE MECANIQUEMENT SUR UNE OSSATURE METALLIQUE EST UNE PLAQUE DE PLATRE.

AVANTAGES DE LA CONSTRUCTION:

  • PERMEABILITE A LA VAPEUR D’EAU
  • ETANCHEITE A L’AIR
  • AFFAIBLISSEMENT ACOUSTIQUE
CONDUCTIVITE THERMIQUEmmU [W/m2K]
ICYNENE H2FOAM LITE (LDC-50)2000.19
ICYNENE H2FOAM LITE PLUS (LDC-70)-0.18
ICYNENE H2FOAM FORTE (MDR-210)-0.16
PARAMETRES TECHNIQUES DE LA CONSTRUCTION
REF.ELEMENTSmmDESCRIPTION
1PLAQUES DE PLATRE12.5PAREMENT INTERIEUR
2RAIL, FOURRURE, LISSE, SYSTEME DE FIXATION-OSSATURE METALLIQUE
3MOUSSE ISOLANTE ICYNENE200EPAISSEUR DE MOUSSE
4BLOC BETON OU BRIQUE200/400MUR




Pose plancher bois


PARAMETRES TECHNIQUES DE LA CONSTRUCTION
REF.MATERIAUmmDÉSCRIPTION
1PANNEAU BOIS20PLANCHER BOIS
2PARE VAPEUR COURANT0,1
POLYETHYLÉNE
3ICYNENE300ISOLANT THERMIQUE PROJETÉ IN SITU

 

Valeurs R requises en France 

Performances thermiques minimales requises pour paroi en rénovation : R ≥  4 m².k/W

Performances thermiques minimales requises pour paroi en neuf :  R  ≥  5 m².k/W




Pose sous solives


PARAMETRES TECHNIQUES DE LA CONSTRUCTION
REF.MATERIAUmmDÉSCRIPTION
1PLAQUE DE PLAQUE CARTONNÉE10PAREMENT INTÉRIEUR
2PARE VAPEUR COURANT0.1POLYETHYLÉNE
3FOURRURE MÉTALLIQUE, LISSE, SUSPENTE AVEC RUPTURE DE PONTS THERMIQUES
4SOLIVE55x160BOIS
5ICYNENE300ISOLANT THERMIQUE PROJETÉ IN SITU
ICYNENE400ISOLANT THERMIQUE PROJETÉ IN SITU
6PANNEAU BOIS20PLANCHER BOIS

 

Valeurs R requises en France

Performances thermiques minimales requises pour paroi en rénovation : R ≥  4 m².k/W

Performances thermiques minimales requises pour paroi en neuf :  R  ≥  5 m².k/W