Structure characteristicts:
EXISTING WALL DONE FROM BRICKS, INSULATED WITH THERMAL INSULATION ICYNENE TO BEARING STRUCTURE OF EXTERNAL FINISHING. VENTED AIRSPACE IS CREATED BY SUPPORTING STRUCTURES AND EXTERNAL FINISHING LAYER IS FIXED / GLUED TO THEM.
Structure advantages:
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540 | |||
---|---|---|---|
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K] | 0.3 | ||
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K] | 0.29 | ||
ICYNENE H2FOAM LITE (LDC-50) | 0.38 | ||
ICYNENE H2FOAM LITE PLUS (LDC-70) | 0.36 | ||
ICYNENE H2FOAM FORTE (MDR-210) | 0.32 | ||
TECHNICAL PARAMETERS OF STRUCTURE | |||
LABEL | LAYER | THK. [mm] | DESCRIPTION |
1 | BRICKS / POROTHERM / HELUZ / YTONG | 450 | EXISTING BEARING STRUCTURE |
2 | TI ICYNENE - SUPPORTING PROFILES FROM AL, ZINC STEEL, WOOD | 100 | THERMAL INSULATION LAYER - BEARING STRUCTURE OF EXTERNAL FINISHING |
3 | AIRSPACE WITH ALLUMINIUM - ZINC Z PROFILE | 40 | VENTED AIRSPACE - SUPPORTING STRUCTURE OF EXTERNAL FINISHING |
4 | METAL SHEET / FUNDERMAX / CETRIS / CEMBONIT / NOVABRIK / KRONOPLAN | 8-35 | EXTERNAL FINISHING |