Structure characteristicts:
Structure advantages:
THERMAL TRANSMITTANCE VALUE ACCORDING TO B.S.EN | |||
---|---|---|---|
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K] | 0.24 | ||
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K] | |||
ICYNENE H2FOAM LITE (LDC-50) | 0.19 | ||
ICYNENE H2FOAM LITE PLUS (LDC-70) | 0.18 | ||
ICYNENE H2FOAM FORTE (MDR-210) | 0.16 | ||
TECHNICAL PARAMETERS OF STRUCTURE | |||
LABEL | LAYER | THK. [mm] | DESCRIPTION |
1 | SLATES/TILES | — | ROOF COVERING |
2 | BATTEN | — | SUPPORT STRUCTURE BASED ON ROOF COVERING |
3 | BREATHER MEMBRANE | 0.2 | WEATHER RESISTANT BARRIER / VAPOUR OPEN PERMEABLE UNDERLAY |
4 | RAFTER - ICYNENE | 140 | RAFTER 120/140, 400-600MM CENTRES / THERMAL INSULATION LAYER |
5 | FURRING CHANNELS - ICYNENE | 60 | SUPPORTING STRUCTURE / THERMAL INSULATION LAYER |
6 | PLASTER BOARD | 12.5 | INTERNAL FINISH |