image_pdf

PLASTIC WINDOW HEAD INSULATION

Structure characteristicts:

BEARING STEEL STRUCTURE WITH METAL SHEET CLADDING WITH THERMAL INSULATION ICYNENE SPRAYED ON CONTACT DIFUSION FOIL. FOIL IS FIXED TO THE FURRING CHANNELS AND INTERNAL FINISHING IS DONE FROM GYPSUM BOARD.

Structure advantages:

  • DIFUSION OPEN
  • AIRTIGHTEN
  • ACOUSTIC RESISTANCE
  • SPEED OF ERECTION
  • TIMBER PARTS INVISIBLE FROM INTERIOR
  • RENEWABILITY OF EXISTING INSULATION WITOUT INTERVENTION TO INTERIOR
THERMAL TRANSMITTANCE VALUE ACCORDING TO CSN 730540
REQUIRED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.3
CALCULATED THERMAL TRANSMITTANCE VALUE U [W/m2K]0.22
ICYNENE H2FOAM LITE (LDC-50)0.21
ICYNENE H2FOAM LITE PLUS (LDC-70) 0.20
ICYNENE H2FOAM FORTE (MDR-210) 0.18
TECHNICAL PARAMETERS OF STRUCTURE
LABELLAYERTHK. [mm]DESCRIPTION
1GYPSUM BOARD15INTERNAL FINISHING
2FURRING CHANNELS60SUPPORTING STRUCTURE
3IPE STEEL PROFIL170STEEL BEARING STRUCTURE
4WÜRTH THERMO ND / STAMISOL0.2DIFFUSION OPEN MEMBRANE
5TI ICYNENE - METSEC PROFILE180THERMAL INSULATION LAYER
6AIRSPACEmin 40VENTED AIRSPACE
7METAL SHEET / FUNDERMAX / CEBRIT / CEMBONIT8-35EXTERNAL FINISHING